    ETS 3200是一款具有數(shù)字顯示的緊湊型電子溫度開關(guān)。

    憑借其集成的溫度探頭,ETS 3200特別適合直接油箱安裝,并有多種長(zhǎng)度可供選擇。

    具有一個(gè)或兩個(gè)開關(guān)輸出和可選的附加模擬輸出信號(hào)的不同輸出版本,提供了多種應(yīng)用可能性。

    使用按鍵板可以非?焖俸洼p松地調(diào)整開關(guān)點(diǎn)和相關(guān)的滯后。

    Specifications

    Type

    Electronic Temperature Switch

    Model Code Description

    ETS 3226-2-018-000

    Direct Current (DC) Supply Voltage When Applied According to UL Specifications (Without Analog Output)

    9 to 35 V

    Note for Direct Current (DC) Supply Voltage When Applied According to UL Specifications

    Limited energy - According to 9.3 UL 61010; Class 2; UL 1310/1585; LPS UL 60950

    Maximum Current Consumption (With Inactive Switching Output)

    35 mA

    Maximum Current Consumption (With Inactive Switching Output and Analog Output)

    55 mA

    Display

    4-Digit, LED, 7 Segment, Red, Height of Digits 7 mm

    Weight

    ~135 g

    Material of Connection

    Stainless Steel

    Seal Material

    Fluoroelastomer (FKM)

    Maximum Output Permitted Load Resistance

    500

    Minimum Output Permitted Load Resistance

    1 k

    Switching Function

    Switching direction of the switching outputs adjustable (N/C or N/O)

    Electrical Connection

    Male M12x1, 4 Pole

    CUL®US Mark

    Certificate No.: E318391

    Note for CUL®US Mark

    Environmental conditions according to 1.4.2 UL 61010-1; C22.2 No. 61010-1

    Switch Point

    -23 to 100 ºC-9 to 212 ºF

    Hysteresis (Switch Point)

    1.0 to 123.5 ºC2 to 222 ºF

    Residual Ripple of Supply Voltage

    ≤ 5 %

    Increment (Switch Point)

    0.5 ºC1.0 ºF

    Note for Increment (Switch Point, Window Function)

     
    All ranges given in the table can be adjusted by the increments shown.

    Lower Switch Value (Window Function)

    -23 to 97.5 ºC-9 to 208 ºF

    Upper Switch Value (Window Function)

    -22 to 98.5 ºC-7 to 209 ºF

    Increment (Window Function)

    0.5 ºC1.0 ºF

    Maximum Total Current Consumption

    2.455 A

    Modification Number

    000

    Switching Outputs

    2 Switching Outputs

    Division

    17

    BUn

    EA

    Input Data

    Measuring Range

    -25 to 100 ºC-13 to 212 ºF

    Input Probe Length

    0.71 in18 mm

    Input Pressure Resistance

    8700 psi

    Input Mechanical Connection

    G1/2 A DIN 3852 (Male)

    Torque Value

    45 N·m33 lb·ft

    Input Mechanical Connection Type

    G1/2 A DIN 3852, Male

    Input Mechanical Connection Size

    G1/2, Male

    Output Data

    Accuracy at Room Temperature

    ≤ ± 2.0ºF (+/- 1.0ºC)

    Operating Temperature [Min]

    -25 ºC-13 ºF

    Operating Temperature [Max]

    100 ºC212 ºF

    Output Temperature Drift at Maximum Zero Point and Range (Full Scale)

    ≤ ± 0.0085% %/°F

    Switch Outputs

    Switch Outputs Type

    PNP Transistor Switching Output

    Maximum Switching Current Per Switch Output

    1.2 A

    Switching Cycles In Million

    > 100 million

    Rise Time to DIN EN 60751 for t50

    3 s

    Rise Time to DIN EN 60751 for t80

    9 s

    Environmental Conditions

    Ambient Temperature Range

    -13 to 140 ºF

    Ambient Temperature Range

    -13 to 176 ºF

    Sensing Temperature [Max]

    100 ºC212 ºF

    Sensing Temperature [Min]

    -25 ºC-13 ºF

    Storage temperature range

    -40 to 176 ºF

    Fluid temperature range

    -13 to 212 ºF

    Note for Fluid Temperature Range

    -13 °F with FPM seal, -40 ºF on request

    CE Mark

    CE Mark EN 61000-6-1/2/3/4

    Vibration Resistance According to DIN EN 60068-2-6 at 0 to 500 Hz

    ≤ 10 g

    Shock Resistance According to DIN EN 60068-2-29 (11 ms)

    ≤ 50 g

    Protection class to IEC 6529

    IP 67

    Pin Connections

    Pin Connection 1

    +UB

    Pin Connection 2

    SP2

    Pin Connection 3

    0 Voltage

    Pin Connection 4

    SP1

    Dimensions

    Sensor Diameter

    6 mm

    Sensor Length

    18 mm

    Length

    42 mm

    Width

    40.4 mm

    Setting Options

    All the settings available on the ETS 3200 are combined in 2 easy-to navigate menus. To prevent unauthorized adjustment of the instrument, a programming lock can be set.

    Additional Information

    For optimum adaptation to the particular application, the instrument has many additional adjustment parameters (e.g. switching delay times, N/C / N/O function, etc.).

    Accessories

    Appropriate accessories, such as electrical connectors, protective sleeves for tank mounting, splash guards, etc. can be found in the Accessories brochure.

    Special Features

     

    • 2 switching outputs, up to 1.2 A load per output.
    • Optional analog output signal selectable (4 .. 20 mA, 0 .. 10 V)
    • 4-digit display
    • Optimum alignment - display can be rotated in two planes (axes)
    • Switching / switch-back points and many useful additional functions can be set using the keypad.
    • Display of temperature and unit of measurement in ºC or ºF
    • Switching mode of the switching outputs adjustable (switching point function or window function)
    • Switching direction of the switching outputs adjustable (N/C or N/O)
    • Switch-on and switch-off delay adjustable from 0.00 .. 99.99 seconds
    • Choice of display (actual temperature, peak temperature, switching point 1, switching point 2, display off)

     

    Note

    Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.

    Subject to technical modifications.

    更多賀德克產(chǎn)品請(qǐng)咨詢賀德克電氣服務(wù)商http://hydac.gongboshi.com/

    无码精品a∨在线观看中文_精品亚洲成A人片在线观看_亚洲人成亚洲人成在线观看_天堂在线中文
  • <samp id="pv2xq"><tbody id="pv2xq"><tt id="pv2xq"></tt></tbody></samp>
  • 
    
  • <rp id="pv2xq"><acronym id="pv2xq"></acronym></rp>